Our cables

A cable for every situation.

Floor heating, concrete slabs, snow melting, roofs, pipes, drinking water and industrial heat tracing: the full Drexma and Elec-Trace range, with specifications, installation guides and warranties.

9
cable families
3.7–15 W
per linear foot
120–600 V
available voltages
Lifetime
3.7 W flexible warranty
The full range

Nine cable families, one standard: reliability.

Scroll to move from one cable to the next. Each entry brings together the key specifications, warranty and downloadable documents.

01 / 09Plancher chauffant surface
3,7 W6 W9 W15 WTLC-TP · MVP-TPREM · TLC-TP · MWTREM-PW · TLC-PWMVL · MVM · MVH · MVUDryPaths
3,7 W
01 / 09 · Surface floor heating

3.7 W

Cable for membranes and guides

Twin-conductor cable designed for uncoupling membranes and plastic guides, under tile, stone, laminate or engineered wood. Even radiant heat, approved for showers.

Voltage
120 V / 240 V
Output
3.7 W/ft (12.14 W/m)
Length
33 to 990 ft (12.2 to 243.8 m)
Diameter
3/16 in (4.7 mm)
Cold lead
10 ft (3 m)
Max. ambient temp.
105 °C (220 °F)
  • Twin conductor with single-point connection
  • Tin-coated element prevents copper oxidation
  • Zero electromagnetic field emissions
Lifetime flexible warrantyCSA certifiedShower approved
02 / 09 · Interior concrete slab

6 W

Embedded cable and mats

Cable and mats embedded in interior concrete slabs for warm, silent basements, garages and workshops. Also available as a self-adhesive mat for faster installation.

Voltage
240 V
Cable output
5.5 W/ft (18 W/m)
Mat output
11 W/sq ft (118 W/m²)
Length
55 to 680 ft (16.8 to 207.3 m)
Diameter
¼ in (6.5 mm)
Cold lead
10 ft (3 m)
  • Single-point connection, stranded twin conductor
  • Silent, efficient and EMF-free
  • Floor sensor included with mats
25-year limited warrantyCSA certified
03 / 09 · Large commercial slabs

9 W

Smart Drexma 347 V mat

347 V embedded mat designed for large interior concrete slabs in commercial and institutional buildings. Approved for 30-amp circuits.

Voltage
347 V
Output
11.25 W/sq ft (120 W/m²)
Size
16.7 to 345.8 ft × 2 ft
Diameter
¼ in (6.5 mm)
Jacket
TPU
Cold lead
20 ft (6 m)
  • 30-amp approved
  • Single-point connection
  • Zero electromagnetic field emissions
25-year limited warrantyCSA certified
04 / 09 · Outdoor snow melting

15 W

SafeWalk cable and mats

For driveways, walkways, stairs and ramps in concrete, asphalt, pavers, natural stone or tile. New tougher FEP jacket and a reinforced cold lead that resists kinking.

Voltage
240 V / 600 V · others on request
Cable output
15 W/ft (49 W/m)
Mat output
45 W/sq ft (480 W/m²)
Length
18 to 768 ft (5.5 to 234.1 m)
Jacket
FEP
Max. ambient temp.
200 °C (392 °F)
  • No more shovelling or salt
  • Controlled by snow and moisture sensors
  • Reinforced 20 ft (6 m) cold lead
10-year limited warrantyCSA certified
05 / 09 · Self-regulating · Roofs and gutters

TLC-TP · MVP-TP

Roof and gutter de-icing

Self-regulating cables that adjust their output to the temperature to prevent ice dams and keep gutters and downspouts flowing. Shingles, metal, slate, membrane or batten roofs.

Models
TLC-TP 12 mm · MVP-TP 13 and 15.4 mm
Output at 10 °C
6, 8, 10, 12 or 15 W/ft
Voltage
120 V / 208–277 V
Plug-and-play
6TLC-TP-PA, 10 ft cold lead
Jacket
Thermoplastic
Installation
Cut to length, can overlap
  • Will not overheat, even when overlapped
  • Tinned copper braid for added protection
  • Works with gutter moisture sensors
10-year warrantycETLus · CSA
06 / 09 · Self-regulating · Pipes

REM · TLC-TP · MWT

Pipe freeze protection

Freeze protection for steel, aluminum and plastic (PVC, ABS, PEX, CPVC) pipes, tanks and valves. MWT keeps hot water at the right temperature in condo towers and large buildings.

Models
REM 8 mm · TLC-TP 12 mm · MWT
Output at 10 °C
3 to 10 W/ft
Voltage
120 V / 208–277 V
Hot water maintenance (MWT)
45, 55 or 70 °C
Min. installation
−40 °C (REM)
Plug-and-play
6TLC-TP-PA with plug
  • Energy efficient: output follows temperature
  • Lower installed cost than steam tracing
  • Optional plug-in TC-2000 thermostat
10-year warrantycULus · cETLus · CSA
07 / 09 · Elec-Trace Aqua · Drinking water

REM-PW · TLC-PW

In-pipe drinking water cable

Self-regulating cables installed inside the pipe: lake water intakes, cottage supply lines, livestock waterers, septic tanks and drains. NSF/ANSI 61 certified for drinking water.

Models
3REM-PW-PA · TLC-PW · 6TLC-PW
Voltage
110–120 V / 208–277 V
Jacket
Fluoropolymer
Max. maintained temp.
65 °C (150 °F)
Installation
In-pipe, brass fitting
Certification
NSF/ANSI 61
  • No overheating, even when overlapped
  • Cut to length on site, no waste
  • Ready-to-plug 120 V versions
5-year warrantyNSF/ANSI 61
08 / 09 · Elec-Trace Industrial

MVL · MVM · MVH · MVU

Industrial heat tracing

Self-regulating heat tracing for pipelines, tanks and valves in industrial and hazardous locations, from freeze protection to process maintenance up to 210 °C.

Low temperature
MVL · MLL (long lines)
MVM
Maintains up to 110 °C
MVH
Maintains up to 150 °C
MVU
Up to 210 °C, 260 °C exposure
Hazardous locations
CSA Class I, Div. 2
Min. installation
−60 °C (MVU)
  • Class I, Div. 1 explosion-proof accessories
  • Flame-retardant fluoropolymer jacket
  • Tracon, Pyrocon and FPC-02 controllers
10-year warrantyCSA hazardous locations
09 / 09 · DryPaths · Snow-melting mats

DryPaths

Plug-in heated mats

Rubber heated mats that sit right on your existing steps, landings and walkways. Plugged into a 120 V outlet, they clear snow and ice with no shovel or salt.

Step DP-0922
9 × 22 in · 60 W
Step DP-3810
38 × 10 in · 120 W
Landing DP-2736
27 × 36 in · 270 W
Walkway DP-2755
27 × 55 in · 420 W
Walkway DP-2478
24 × 78 in · 540 W
15 A / 120 V circuit
1,440 W max. combined
  • No permanent installation
  • DS-5C-DP and DS-9C-DP snow controllers
  • Ideal for hot tubs, entrances and access ramps
Plug-in 120 V
Warranties and certifications

Some of the longest warranties in the industry.

Every cable is tested and certified for the Canadian and US markets. Full terms are in each cable’s warranty document.

Lifetime
Flexible

3.7 W cable and DrexMat-Heat membrane.

25 years
Limited

6 W cables and mats and 9 W mats for interior concrete slabs.

10 years
Warranty

15 W snow-melting cables and all our self-regulating cables.

5 years
Aqua

Elec-Trace Aqua drinking water cables.

5 years
Thermostats

A five-year warranty on our thermostats, rare in the industry.

CSA

All our cables are tested and certified to Canadian and US standards, including for hazardous locations.

cULus

REM, REM-PW and 6TLC-TP-PA, with regular audits at the factory.

cETLus

TLC-TP and 6TLC-TP-PA, compliant with North American safety requirements.

NSF/ANSI 61

TLC-PW and REM-PW, safe for drinking water systems.

Thermostats and controls

The right control for every system.

Smart thermostats, snow-melting controllers and freeze-protection controls, selected to work with our cables.

Drexma WiStat
Drexma

WiStat

Thermostat intelligent programmable et tactile, Wi-Fi 2,4 et 5 GHz, compatible Alexa et Google Assistant.

Wi-FiTactileCommande vocale
Manuel ↗
Drexma UDG
Drexma

UDG

Thermostat programmable et tactile, blanc ou noir, 120/240 V, 15 A, 3 600 W.

ProgrammableTactile
Manuel ↗
OJ Electronics UWG5-4999
OJ Electronics

UWG5-4999

Thermostat Wi-Fi et Bluetooth programmable avec commande vocale, nouvelle version du UWG4.

Wi-FiBluetoothCommande vocale
Manuel ↗
OJ Electronics UTN5-4999
OJ Electronics

UTN5-4999

Thermostat tactile non programmable, simple et élégant.

TactileNon programmable
Manuel ↗
OJ Electronics USG5-4000
OJ Electronics

USG5-4000

Module d’alimentation relais pour les grandes surfaces, compatible avec les thermostats OJ et le WiStat.

Module
Manuel ↗
Sinopé TH1320WF
Sinopé

TH1320WF

Thermostat intelligent Wi-Fi pour plancher chauffant, 3 600 W.

Wi-Fi3 600 W
Sinopé TH1400WF
Sinopé

TH1400WF

Thermostat intelligent Wi-Fi pour chauffage basse tension 24 Vca.

Wi-Fi24 Vca
Sinopé TR1310
Sinopé

TR1310

Module d’expansion 3 600 W non programmable pour thermostat de plancher chauffant.

Module3 600 W
ETI PD PRO
ETI

PD PRO

Contrôle automatique de fonte de neige et de glace, 1 × 30 A, 100–277 V.

30 A100–277 V
Manuel ↗
ETI GF PRO
ETI

GF PRO

Contrôleur de fonte de neige avec protection intégrée contre les défauts à la terre (DDFT), 1 × 30 A.

DDFT30 A
Manuel ↗
ETI LCD-8 Snow Switch
ETI

LCD-8 Snow Switch

Contrôleur automatique configurable de fonte de neige et de glace, 100–240 V.

Configurable
Manuel ↗
ETI Snow Owl CIT-2
ETI

Snow Owl CIT-2

Capteur aérien de neige et de glace 24 V pour les systèmes de gestion de surface.

Capteur24 V
Manuel ↗
Meitav-Tec Pyrocon 19
Meitav-Tec

Pyrocon 19

Contrôleur intelligent 5 zones avec écran LCD rétroéclairé et communication Modbus / BACnet.

5 zonesModbusBACnet
Manuel ↗
Meitav-Tec Pyroself X-Kit
Meitav-Tec

Pyroself X-Kit

Sonde et contrôleur aériens autonomes avec contacteurs 2 × 24 A, télécommande incluse.

Autonome2 × 24 A
Manuel ↗
Meitav-Tec Pyrobox
Meitav-Tec

Pyrobox

Panneau de gestion de fonte de neige avec relais de fuite à la terre, Modbus / BACnet et Wi-Fi en option.

PanneauWi-Fi
OJ Electronics ETO2
OJ Electronics

ETO2

Contrôleur de fonte de neige et de glace à 2 zones (3 × 16 A), 120–240 V.

2 zones
Manuel ↗
OJ Electronics ETOP-4770
OJ Electronics

ETOP-4770

Contrôleur de fonte de neige et de glace, capacité de charge 1 × 30 A.

30 A
Manuel ↗
ASE DS-5C · DS-9C
ASE

DS-5C · DS-9C

Détecteurs de neige avec sonde d’humidité et de température, 2 × 30 A, 120–240 V.

2 × 30 A
Manuel ↗
Chrystal CPC401
Chrystal

CPC401

Contrôleur intelligent Wi-Fi pour piloter vos systèmes de fonte de neige à distance.

Wi-FiApplication
Manuel ↗
ETI Tracon FPT-130
ETI

Tracon FPT-130

Contrôleur de protection contre le gel une zone avec DDFT, 30 A, réglable à −1, 4, 7 ou 10 °C.

DDFT30 A
Manuel ↗
ETI Tracon GPT-130
ETI

Tracon GPT-130

Contrôleur de température une zone, relais 30 A et DDFT 30 mA, réglable de −12 à 537 °C.

DDFT30 A
Manuel ↗
ETI Tracon GPT-230
ETI

Tracon GPT-230

Contrôleur de température deux zones, 2 × 30 A, 100–277 V, avec DDFT.

2 zonesDDFT
Manuel ↗
Meitav-Tec FPC-02
Meitav-Tec

FPC-02

Contrôleur de protection contre le gel 1 × 30 A, 120 ou 240 V, DDFT et sonde de 9,75 m. Version extérieure disponible.

DDFT30 A
ETI GIT-1
ETI

GIT-1

Sonde d’humidité pour le dégivrage automatique des gouttières et toitures, pour contrôleurs ETI.

CapteurGouttières
Manuel ↗
ThermaCord TC-2000
ThermaCord

TC-2000

Cordon prêt à brancher 120 V avec interrupteur thermostatique : s’allume à 3 °C et s’éteint à 10 °C.

120 VPrêt à brancher
Manuel ↗
Snovate FP-X1
Snovate

FP-X1

Thermostat 120 V, 15 A avec fiche à trois broches pour câbles prêts à brancher.

120 V15 A
Manuel ↗
Thermocube
Thermocube

Thermocube

Thermostat prêt à brancher qui s’active à 3 °C (38 °F), 1 800 W max. en 120 V.

120 V1 800 W
Johnson Controls A421-AEC-02C
Johnson Controls

A421-AEC-02C

Thermostat électronique réglable pour la dalle, l’air ambiant ou le tuyau, sonde de 6 pi.

Électronique
Manuel ↗
PECO TRF115
PECO

TRF115

Thermostat mécanique 25 A, 120–277 V, pour la surtempérature en dalle, sur tuyau ou ambiante.

25 AMécanique
Manuel ↗

Need help choosing the right cable?

Our specialists help you size your system and choose the right control, free of charge.